text/plain (148 lines)

Thanks Charlie,

This is a valuable breakdown of RH issues.

One question for Randye: I notice you're in Iowa. Consequently, and  
as Charlie mentions,
you likely see RH fluctuations from season to season. I agree that  
20-30% RH is great for
the storage of AV media and playback equipment but, if your RH jumps  
to 75-80% in the
summertime - which is entirely possible in the Midwest - you're  
really giving your AV holdings
a beating.

I often make an allusion in these cases to musical instruments,  
especially stringed instruments:
You know how they can go in and out of tune when taken from the house  
into the cold and then
back into another building? The same expansion and contraction  
affects AV media as well,
something that will compromise their stability over time. (Nitrate  
layers on lacquer discs, for example.)

So fluctuations in RH are equally important to monitor and keep under  
control. And in this case,
i might actually argue that an RH closer to 40-50% makes sense in the  
winter if (**and only if**)
your summer RH levels are in the neighborhood of 70-80%.

At least it would ease the whiplash caused by radical (20% --> 70% -- 
 > 20% etc) RH fluctuations.

cheers,
Brandon


____________________________________
Brandon Burke
Archivist for Recorded Sound Collections
Hoover Institution Archives
Stanford University
Stanford, CA 94305-6010
vox: 650.724.9711
fax: 650.725.3445
email: [log in to unmask]





On Dec 4, 2008, at 10:16 AM, Charles A. Richardson wrote:

> Hi Randye:
>
> Humidity levels are relative to temperature.  You did not indicate  
> the temperatures involved.  The thing to do is have good  
> instruments to watch and measure both temperature and humidity  
> readings periodically.  You will notice major changes with the four  
> seasons of the year and also perhaps with the number of people in  
> the room.
>
> The low humidity is good for both media and equipment as it retards  
> various negative unwanted chemical reactions and also keeps down  
> the risk of the growth of mold and fungus.   Humidity of 20% to 30%  
> is excellent for media and is typically recommended in various well  
> established long term storage standards for many chemical reasons.
>
> Your note did not mention heating and air conditioning issues.  Air  
> Conditioning dehumidifies and removes moisture when it drops the  
> air temperature.  Heating is of different kinds.  If the heating is  
> by radiators, or electric coil heaters, these tend to dry out the  
> air and drop the humidity.   Heating by forced air systems may or  
> may not have a humidifier in the furnace room which can be adjusted  
> to add humidity moisture as desired and specified to the warm air  
> circulated through the system.   As I do not know any of these  
> heating and cooling issues in detail, I simply make the above  
> general comments.
>
> Evidently the staff or others are feeling some discomfort at the  
> lower humidity levels, with perhaps dry throats, etc.
> If the humidity is raised for people, then this is not good for the  
> media and equipment, so there is a bit of a conflict on the  
> humidity issue.  The best thing is to leave the room humidity as it  
> is, not add a humidifier, and for those who feel dried out to drink  
> some water, soft drinks, etc. occasionally to re-hydrate  
> themselves.   Most places have humidity levels that are way too  
> high and thus have lots of high humidity related media and  
> equipment problems. They have to use dehumidifiers to get rid of  
> the high moisture.   So consider yourself fortunate not to have the  
> high humidity problem.  If people will drink more water based  
> liquids, then everyone and everything should be happy.
>
> Also another issue not mentioned that may be a factor in staff  
> discomfort is Oxygen levels and Carbon Dioxide levels.  If the
> room is tightly sealed and does not get fresh air circulation  
> occasionally,  and there are a lot of people in the room, they can  
> consume a fair amount of Oxygen, just from ordinary breathing.  The  
> Carbon Dioxide levels will also then go up, and this can make  
> people feel stuffy, drowsy,  or uncomfortable.  It might be a good  
> thing to look into the fresh air and Oxygen level issue just to be  
> sure things are OK on this front, especially when a lot of people  
> have been in the room for a long time.  Are doors closed or open?
>
> Hope this helps.   Charlie Richardson
>
>
>
> On Dec 4, 2008, at 11:39 AM, Jones, Randye wrote:
>
>> Good day, all!
>>
>>
>>
>> We are considering installing a humidifier to address the low  
>> humidity (21-22% at present) in our library's Listening Room.   
>> However, I'm very concerned about whether it would adversely  
>> affect the audio and video equipment and/or the video and audio  
>> collections housed here.
>>
>>
>>
>> One thing we are considering is placing the humidifier in the  
>> outer public area so that the steam generated would be less likely  
>> to directly contact the equipment or collections.
>>
>>
>>
>> What is your experience?  It has been suggested that the higher  
>> humidity would not only benefit the staff but the materials in the  
>> room.
>>
>>
>>
>> Thanks for any input you can provide.
>>
>>
>>
>> Regards,
>>
>> Randye
>>
>> -=*=-=*=-=*=-=*=-=*=-=*=-=*=-=*=-=*=-=*=-=*=-=*=-=*=-
>>    |      | Randye Jones
>>    | )    | Listening Room Supervisor
>>  / |      | Grinnell College Libraries, Grinnell, IA 50112
>> (   |   )  | [log in to unmask]
>>    |      | Phone: 641-269-3365 FAX: 641-269-4283

Top of Message | Previous Page | Permalink

Advanced Options


Options

Log In

Log In

Get Password

Get Password


Search Archives

Search Archives


Subscribe or Unsubscribe

Subscribe or Unsubscribe


Archives

March 2024
February 2024
January 2024
December 2023
November 2023
October 2023
September 2023
August 2023
July 2023
June 2023
May 2023
April 2023
March 2023
February 2023
January 2023
December 2022
November 2022
October 2022
September 2022
August 2022
July 2022
June 2022
May 2022
April 2022
March 2022
February 2022
January 2022
December 2021
November 2021
October 2021
September 2021
August 2021
July 2021
June 2021
May 2021
April 2021
March 2021
February 2021
January 2021
December 2020
November 2020
October 2020
September 2020
August 2020
July 2020
June 2020
May 2020
April 2020
March 2020
February 2020
January 2020
December 2019
November 2019
October 2019
September 2019
August 2019
July 2019
June 2019
May 2019
April 2019
March 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
June 2018
May 2018
April 2018
March 2018
February 2018
January 2018
December 2017
November 2017
October 2017
September 2017
August 2017
July 2017
June 2017
May 2017
April 2017
March 2017
February 2017
January 2017
December 2016
November 2016
October 2016
September 2016
August 2016
July 2016
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
December 2015
November 2015
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
April 2015
March 2015
February 2015
January 2015
December 2014
November 2014
October 2014
September 2014
August 2014
July 2014
June 2014
May 2014
April 2014
March 2014
February 2014
January 2014
December 2013
November 2013
October 2013
September 2013
August 2013
July 2013
June 2013
May 2013
April 2013
March 2013
February 2013
January 2013
December 2012
November 2012
October 2012
September 2012
August 2012
July 2012
June 2012
May 2012
April 2012
March 2012
February 2012
January 2012
December 2011
November 2011
October 2011
September 2011
August 2011
July 2011
June 2011
May 2011
April 2011
March 2011
February 2011
January 2011
December 2010
November 2010
October 2010
September 2010
August 2010
July 2010
June 2010
May 2010
April 2010
March 2010
February 2010
January 2010
December 2009
November 2009
October 2009
September 2009
August 2009
July 2009
June 2009
May 2009
April 2009
March 2009
February 2009
January 2009
December 2008
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
December 2007
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007
December 2006
November 2006
October 2006
September 2006
August 2006
July 2006
June 2006
May 2006
April 2006
March 2006
February 2006
January 2006
December 2005
November 2005
October 2005
September 2005
August 2005
July 2005
June 2005
May 2005
April 2005
March 2005
February 2005
January 2005
December 2004
November 2004
October 2004
September 2004
August 2004
July 2004
June 2004
May 2004
April 2004
March 2004
February 2004
January 2004
December 2003
November 2003
October 2003
September 2003
August 2003
July 2003
June 2003
May 2003
April 2003
March 2003
February 2003
January 2003

ATOM RSS1 RSS2



LISTSERV.LOC.GOV

CataList Email List Search Powered by the LISTSERV Email List Manager