Subject:

Re: Test tones circa 1978

From:

"Richard L. Hess" <[log in to unmask]>

Reply-To:

Association for Recorded Sound Discussion List <[log in to unmask]>

Date:

Fri, 28 Jan 2011 19:56:15 -0500

Content-Type:

text/plain

Parts/Attachments:

Parts/Attachments

text/plain (111 lines)

Hi, Bob and Tom,

The guarantee of x number of cycles per year (which was the old thing to 
keep the clocks on time) is pretty much a thing of the past now that we 
have the huge grids of interconnected generating stations. They are 
generally run now on GPS-derived frequency standards and, since the 
1950s, the frequency standard of the power lines in the U.S. and Canada 
(where they are grid-connected) has improved greatly.

If you look here, you will see that there are essentially three isolated 
(by DC interconnects) grids in the U.S. and Canada (Alaska, Hawaii, and 
remote portions of Canada, including Newfoundland excluded as they are 
not on the grid, yet). There is the Eastern Interconnect, the Western 
Interconnect, and the ERCOT Interconnect for Texas.

> A generator that drops 2 Hz below 60 Hz will
> rapidly build up enough heat in its bearings
> to destroy itself.

> In the Eastern Interconnect, a
> 30-mHz drop in frequency reduces power
> delivered by 1 GW
That's 0.03 Hz or 0.05%

http://www.aip.org/tip/INPHFA/vol-9/iss-5/p8.html (see map at top)

The 0.03 Hz variation would not be tolerated for long, but that 
corresponds to 1.8 seconds per hour of error, well within the timing 
tolerances of most tape machines.

Another interesting paper showing some limiting conditions
http://gridwise.pnl.gov/docs/pnnlsa44073.pdf

And, for more than you ever wanted to know:
http://www.scribd.com/doc/20275676/Robust-Power-System-Frequency-Control

Anyway, long-term (most frequency disturbances are short term as loads 
change), the strobe is not a bad idea at all. You can use a frequency 
counter to measure the line frequency, but its calibration may be no 
better than the AC line. My used, old Fluke in the studio is doing 
pretty well, but there is ambiguity at the fourth digit on my word clock 
bus. Most of the time it reads 44.10 or 96.00, but sometimes the last 
digit flicks.

Better than the strobe is a tachometer which is what is built into 
modern machines. All of the machines I use have a tachometer on a 
large-diameter roller. That includes the Studer A80, A810, and A807 and 
the Sony APR-5000 and APR-16. You can use external crystal oscillators 
that are accurate and stable as a reference.

As with any measurement, we have to make certain we're not using rubber 
rulers. The larger the grid, the more likely it is to be stable. I would 
suspect the Eastern North America grid is more stable than the Texas one.

No matter how you measure it: strobe, flutter tape, or tachometer, you 
are at the mercy of your measurement timebase. Your local frequency 
counter is probably better than you need for analog tape with any of 
these inputs. Slippage in the tach (electronic or strobe) and stretch, 
wrap issues, and slippage in the flutter test tape all introduce a level 
of uncertainty.

Since most of the above mentioned machines are crystal controlled, 
counting down from the microprocessor clock frequency, the only machine 
type I check regularly is the A80 which uses the analog discriminator on 
the capstan servo (same basic circuit as the A77, but with refinements). 
With that, I measure the tach frequency of the capstan motor and make 
sure it's 1600 Hz.

Cheers,

Richard



On 2011-01-28 6:09 PM, Tom Fine wrote:
> Hi Bob:
>
> Question on that -- if the lights are blinking at the wrong frequency 
> and the tape motor is thus running a bit fast or slow, why wouldn't 
> that register on a calibrated strobe wheel? Won't lights that aren't 
> 60hz make the strobe pattern move just the same as wheel speed that's 
> not right? Sorry if it's a dumb question!
>
> -- Tom Fine
>
> ----- Original Message ----- From: "Bob Olhsson" <[log in to unmask]>
> To: <[log in to unmask]>
> Sent: Friday, January 28, 2011 5:20 PM
> Subject: Re: [ARSCLIST] Test tones circa 1978
>
>
>> -----Original Message-----
>> From Tom Fine: "...Shai -- how about a stroboscope wheel in the tape
>> path?..."
>>
>> I was told when I was working in motion picture post production that
>> unfortunately power line frequencies are not a reliable source of speed
>> calibration because they are adjusted to maintain the long term 
>> accuracy of
>> electric clocks.
>>
>> A flutter tape is really the only solution.
>>
>

-- 
Richard L. Hess                   email: [log in to unmask]
Aurora, Ontario, Canada           (905) 713 6733     1-877-TAPE-FIX
http://www.richardhess.com/tape/contact.htm
Quality tape transfers -- even from hard-to-play tapes.

Top of Message | Previous Page | Permalink

Advanced Options


Options

Log In

Log In

Get Password

Get Password


Search Archives

Search Archives


Subscribe or Unsubscribe

Subscribe or Unsubscribe


Archives

February 2020
January 2020
December 2019
November 2019
October 2019
September 2019
August 2019
July 2019
June 2019
May 2019
April 2019
March 2019
February 2019
January 2019
December 2018
November 2018
October 2018
September 2018
August 2018
July 2018
June 2018
May 2018
April 2018
March 2018
February 2018
January 2018
December 2017
November 2017
October 2017
September 2017
August 2017
July 2017
June 2017
May 2017
April 2017
March 2017
February 2017
January 2017
December 2016
November 2016
October 2016
September 2016
August 2016
July 2016
June 2016
May 2016
April 2016
March 2016
February 2016
January 2016
December 2015
November 2015
October 2015
September 2015
August 2015
July 2015
June 2015
May 2015
April 2015
March 2015
February 2015
January 2015
December 2014
November 2014
October 2014
September 2014
August 2014
July 2014
June 2014
May 2014
April 2014
March 2014
February 2014
January 2014
December 2013
November 2013
October 2013
September 2013
August 2013
July 2013
June 2013
May 2013
April 2013
March 2013
February 2013
January 2013
December 2012
November 2012
October 2012
September 2012
August 2012
July 2012
June 2012
May 2012
April 2012
March 2012
February 2012
January 2012
December 2011
November 2011
October 2011
September 2011
August 2011
July 2011
June 2011
May 2011
April 2011
March 2011
February 2011
January 2011
December 2010
November 2010
October 2010
September 2010
August 2010
July 2010
June 2010
May 2010
April 2010
March 2010
February 2010
January 2010
December 2009
November 2009
October 2009
September 2009
August 2009
July 2009
June 2009
May 2009
April 2009
March 2009
February 2009
January 2009
December 2008
November 2008
October 2008
September 2008
August 2008
July 2008
June 2008
May 2008
April 2008
March 2008
February 2008
January 2008
December 2007
November 2007
October 2007
September 2007
August 2007
July 2007
June 2007
May 2007
April 2007
March 2007
February 2007
January 2007
December 2006
November 2006
October 2006
September 2006
August 2006
July 2006
June 2006
May 2006
April 2006
March 2006
February 2006
January 2006
December 2005
November 2005
October 2005
September 2005
August 2005
July 2005
June 2005
May 2005
April 2005
March 2005
February 2005
January 2005
December 2004
November 2004
October 2004
September 2004
August 2004
July 2004
June 2004
May 2004
April 2004
March 2004
February 2004
January 2004
December 2003
November 2003
October 2003
September 2003
August 2003
July 2003
June 2003
May 2003
April 2003
March 2003
February 2003
January 2003

ATOM RSS1 RSS2



LISTSERV.LOC.GOV

CataList Email List Search Powered by the LISTSERV Email List Manager