Print

Print


In this application, all source machines must be synchronous. That's not possible with the vast majority of DAT machines.


On Aug 11, 2010, at 1:11 PM, Marcos Sueiro Bal wrote:

> Shai,
> 
> We are looking into digitally ingesting several DATs simultaneously,
> via AES -> ADAT. Maximum sample rate is 48.
> 
> Are you referring to the Alesis HD24? I have that unit, but an extra
> (and somewhat slow) step of converting its proprietary files is
> necessary, so it would not be convenient for us.
> 
> Thanks!
> 
> Marcos
> 
> On Tue, Aug 10, 2010 at 6:28 PM, Shai Drori <[log in to unmask]> wrote:
>> Hi Marcos
>> The unit you look at has a limit to 48kHz sampling rate. I personally use
>> ADAT 24 track ingest system with great results. Never used the AES. Why do
>> want to use it? do you have long distance from a/d to computer?
>> Shai
>> 
>> On 8/10/2010 10:26 PM, Marcos Sueiro Bal wrote:
>>> 
>>> Greetings!
>>> 
>>> I am curious to know if anyone is doing multi-stream ingest via
>>> parallel AES, and, if so, what their setup is.
>>> 
>>> For example, is anyone familiar with this product? Are there similar
>>> products are there?
>>> http://www.aphex.com/144.htm
>>> 
>>> Thanks much,
>>> 
>>> Marcos
>>> 
>>> 
>> 
> 
> 
> 
> -- 
> Marcos Sueiro Bal
> Audio Engineer
> 718.902.7441
> Follow my blog, The Audio Archivist:
> http://theaudioarchivist.blogspot.com/

David Glasser
Airshow Mastering
Boulder, CO

303-247-9035

www.airshowmastering.com
[log in to unmask]